在快要放弃的时候出现了转机-H3C交换机起死回生一例

昨天重启一台H3C S5024PV2_EI_PWR交换机后,一直连不通,到机房检查发现该设备无法启动,电源灯一直闪烁。

发生什么情况?难道挂了?

接上Console 口看看,能进入 BOOTWARE MENU。但Rom不能启动。

于是,上官网下载最新的Rom用tftp上传到交换机。一切顺利。

可还是不能启动,只能到BOOTWARE MENU

===========================<EXTEND-BOOTWARE MENU>===========================

|<1> Boot System                                                           |

|<2> Enter Serial SubMenu                                                  |

|<3> Enter Ethernet SubMenu                                                |

|<4> File Control                                                          |

|<5> Restore to Factory Default Configuration                              |

|<6> Skip Current System Configuration                                     |

|<7> BootWare Operation Menu                                               |

|<8> Clear Super Password                                                  |

|<9> Storage Device Operation                                              |

|<0> Reboot                                                                |

============================================================================

Ctrl+Z: Access EXTEND-ASSISTANT MENU

Ctrl+F: Format File System

Enter your choice(0-9):

好吧,试试|<5> Restore to Factory Default Configuration。结果提示

Password recovery capability is enabled. To perform this operation, first      

disable the password recovery capability using the undo password-recovery      

enable command in CLI.

Shit,现在进不去CLI怎么搞。

仔细看这个设备的flash只有32M,一个ROM有12M,里面有两个ROM(一个主要的,一个备用的),尝试删除一个不能启动ROM

Deleting the file in flash:

‘M’ = MAIN      ‘B’ = BACKUP      ‘S’ = SECURE      ‘N/A’ = NOT ASSIGNED

============================================================================

|NO. Size(B)   Time                 Type   Name                            |

|1   12280832  Aug/08/2008 20:00:00 M      s5024pv2_ei_pwr-cmw520-r11~001  |

|2   12280832  Aug/08/2008 20:00:00 B      s5024pv2_ei_pwr-cmw520-r11~002  |

|3   1047348   Feb/17/2001 20:22:55 N/A    logfile/logfile.log             |

|4   1584      May/13/2000 22:40:32 N/A    private-data.txt                |

|5   3263      May/13/2000 22:40:44 B      _startup_bak.cfg                |

|6   275       May/13/2000 22:40:40 N/A    system.xml                      |

|7   3641      May/13/2000 22:40:56 M      startup.cfg                     |

|0   Exit                                                                  |

============================================================================

Enter file No:1

The file you selected is flash:/s5024pv2_ei_pwr-cmw520-r1105.bin,Delete it?

[Y/N]Y

Deleting…………………………………………………………..

………………………………………………………………….

………………………………………………………………….

………………………………………………………………….

………………………………………………………………….

………………………………………………………………….

………………………………………………………………….

………………………………………………………………….

………………………………………………………………….

………………………………………………………………….

………………………………………………………………….

等了10分钟还在删除,Shit.难道是因为从终端进去删除一个文件才这么慢吗?

不等了,没有耐心等下去,直接拔电源线。再重启。靠,Extend BootWare菜单都进不去了。

一直停留在BootWare Validating…

但是能进BASIC-BOOTWARE MENU

进去可以刷BOOTWARE,到H3C官网去找,SHit,居然没有下载的。

没办法,打400电话,报上序列号,H3C的工程师热情的告诉我他会把Bootware发到我邮箱,Great。

等了10分钟,收到文件,马上开刷。

一起顺利,刷成功了,重启。

Shit,还是一直停留在BootWare Validating…

反馈给H3C的工程师。把操作记录发给他。对方表示可能是硬件有问题。

并热心的把本地的售后服务中心地址电话发给我。告知可以去更换。

好吧,今晚到此为止,交换机就这样开着。看看明天行不行,不行的话就拿去维修中心更换。

~~~~~~~~~~~~~~~~~~~~~~~~~我是分隔线~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

第二天上班打开终端一看,居然进入Extend BootWare菜单了。

我都准备放弃了,MD居然又可以进了。

赶紧上传一个ROM试试,上传成功,却还是不能登陆。

好吧,Format Flash后再上传一次ROM,居然可以启动了。

狂喜,赶紧配置一下。保存配置,再试一次重启。

重启OK,Great。可是却发现配置文件丢了,难道没有保存成功。

Shit,从终端把password recovery关掉,然后reset to factory default。

一切顺利,保存配置OK。

折腾了两天,这台交换机又起死回生了。

 